A solar plant, storage or both: how much you will save on your bills and, if you already have a generator, on fuel.
Keeps running without power
—h
Savings per year
—UAH
- Sun per year
- —MWh
- Grid electricity
- —UAH/kWh
- Generator electricity
- —UAH/kWh
- A full storage lasts
- —
- Payback
- —
Where the savings come from, UAH a year
Sun instead of the grid—
Storage: cheap hours instead of expensive ones—
Generator fuel and maintenance—
The year by month
- Consumption
- From the sun
- From storage
- To the grid, below the line
kWh per month
A working day
- From the sun
- From storage
- From the grid
- Storage charging
- To the grid
- Plant output
- Price: cheap → expensive
kW
A day with outages
- From the sun
- From storage
- From the grid
- Unpowered
- Storage charging
- Plant output
- No power
kW
Money over 25 years
- Accumulated savings
- Not paid back yet
- Payback
UAH, cumulative
Equipment
Approximate turnkey cost, excl. VAT
We will calculate it exactly from your data
Your numbers go into the request. The engineer will take the metering data, the roof plan and the prices of equipment in stock.
How we calculate
Generation and consumption
- The output of 1 kW of panels for the oblast centre is from PVGIS 5.3 (JRC, SARAH3, average of 2005–2023; crystalline silicon modules, optimal tilt facing south, system losses 14%): from 1,085 kWh a year in Lviv Oblast to 1,276 in Kherson Oblast, month by month for each oblast. A flat roof ×0.92, a ground plant with bifacial modules ×1.08. Each month is made of clear and cloudy days; a cloudy day gives 30% of a clear one. Degradation 0.4% a year from the datasheets.
- Schedules: one shift 8:00–17:00 five days a week, 15% of the load outside working hours; daily 8:00–21:00; two shifts 6:00–22:00 six days a week; around the clock, evenly. We count hour by hour: own use takes the smaller of generation and load, the surplus charges the storage, the rest goes to the grid.
- Recommended power: the largest at which at least 80% of the generation is used on site without storage.
Electricity price
- “Market”: a different price every hour, the average day of each month on the day-ahead market for 27.09.2025–26.09.2026 (JSC Market Operator) + transmission + class 2 distribution (up to 27.5 kV) of the oblast’s main distribution system operator, NEURC tariffs from 01.08.2026; excluding VAT and the supplier’s margin. Electricity is cheaper at night and at midday, more expensive in the morning and in the evening.
- “One price”: a single price for all hours; by default the average DAM price + transmission + distribution, but it is better to enter the price from your bill. The surplus sun is sold at the average DAM price of the sunny hours.
Outages, storage and generator
- The load follows the schedule: the average in working hours from your consumption. “All” is the whole working-hours load, “Half” is half of it, “Custom” is your figure.
- We count the storage as it comes in the kit: batteries and cabinets in whole units, so the capacity may be a little larger than the one entered. Usable capacity 90%, efficiency 90%, and in an hour it charges no more than half its capacity (a full charge takes at least 2 hours). “Backup”: the storage is always full and waits for an outage. “Backup and savings”: the outage reserve (load × hours) is always kept, and the rest of the capacity works twice a day: in the cheap hours (at night 0:00–6:00 and at midday 10:00–17:00) the storage charges fully, first from the surplus sun, the rest from the grid evenly over the cheapest half of those hours, and it supplies your own consumption in the expensive hours (in the morning 6:00–10:00 and in the evening 17:00–24:00), the most expensive first, only when the difference covers the losses; whatever is not needed stays for the next time. The storage does not sell to the grid. Charging from the grid is limited only by the storage’s power or by the “Permitted capacity”, if it is given. With one fixed price the storage shifts the surplus sun to the evening.
- Outages: starting at 9:00 (daytime) or at 18:00 (evening), “Any time” is half and half. The “A day with outages” chart shows a working day of the outage season with your outage length and the power that must keep running. The outages stand where they are usually scheduled: in the morning and in the evening, at the hours of the highest consumption, less often at night; the “Another day” button shows another schedule: morning and evening, evening only, night and late evening, morning only. After an outage the storage recharges. The winter sun is that of December–February. First the sun, then the storage, then the generator. In an outage the plant works only with storage or a generator, otherwise the inverters switch off together with the grid; the sun above the critical load in those hours is lost.
- Without a generator, the energy the sun and the storage give in an outage is counted like ordinary grid energy (the business works as usual), minus recharging the storage after the outage. With a generator it replaces fuel.
- Generator fuel follows a linear consumption curve (as in HOMER Energy): litres per hour = idle share × generator power + consumption per kW of load. Diesel 0.035 and 0.25 l: by the manufacturers’ tables for 20–500 kW generators this is 0.28 l per kWh at full load, 0.32 at half load and 0.39 at a quarter. Petrol 0.07 and 0.38 l. A kilowatt-hour from the generator = fuel × price + maintenance per engine hour, divided by the load. With storage the generator starts only when needed; without it, it runs for the whole outage to hold the grid for the inverters. The fuel price is the average at Ukrainian filling stations on 20.11.2026 (Minfin, data of the A-95 Consulting Group).
Money
- Savings on the bill: the bill without the equipment minus the bill with it, the surplus at the selling price. Maintenance 1% of the cost a year.
- If you have not entered your own sum, we estimate the cost in dollars excluding VAT (in hryvnias at the NBU rate): the equipment at our prices, installation, commissioning, foundations for the cabinets and the crew’s trip to your oblast at our rates, mounting structures, cable products and switchgear at average market prices. Not included: the substation, the design, approvals with the DSO and the connection fee. We confirm the exact cost after a site survey.
- Kit: 650 W TOPCon bifacial panels for roofs and the ground; grid-tie inverters with a panel-to-inverter ratio of about 1.15; storage, whatever comes closest to the required capacity and carries the required power: one or two all-in-one cabinets of 30 kW / 54 kWh or 50 kW / 100 kWh with a panel input; BSM48314 high-voltage batteries of 16.08 kWh in racks of 4–16, one rack per battery input of the hybrid inverter, within its voltage range from the datasheet (battery 44.8–56 V; 125 kW: two inputs of 300–950 V, that is 7–16 batteries; 50 kW: two inputs of 150–800 V, 4–14; 30 kW: one input of 150–800 V, 4–14; the hybrid inverters also take panels); or 125 kW / 261 kWh cabinets. The batteries stand indoors or in a container.